Can't connect to a venue: first checks

What to check when a directConnect handler or FIX session will not connect.

Symptom: the handler or FIX session never connects, connects and drops straight away, or the venue rejects the logon.

Likely causes

  • The host, port or multicast group in your settings doesn't match the venue's environment (production, certification or test).
  • A firewall, VPN or cross-connect isn't open to that address.
  • Credentials, SenderCompID or TargetCompID are wrong, expired or not yet enabled by the venue.
  • The licence file is missing or has expired.
  • Your handler version doesn't support the venue's current protocol or schema version.

Checks

  1. Read the handler log. Most failures are named there: connection refused, timeout, logon reject, or licence error.
  2. From the same host, test the TCP route with nc -vz host port or Test-NetConnection host -Port port on Windows.
  3. For multicast feeds, check that the host has joined the group and that packets arrive, with tcpdump -n multicast -i .
  4. Confirm with the venue which environment and credentials you have been given, and that your IP address is on their allow list.
  5. Check the licence file, as set out in Installing your licence file.
  6. Compare your handler version with the venue's current specification in the release notes.

Fix: correct the setting the log or checks point to, then reconnect. If the cause still isn't clear, email support@onixs.biz with the handler log, the handler version and the venue environment.

Each venue's programming guide sets out its connection settings; the guides are linked from the venue hubs in this category.

 

 

 

Documentation: Programming guides on ref.onixs.biz
Try it: Request a free 30-day evaluation