Can't connect to a venue: first checks
What to check when a directConnect handler or FIX session will not connect.
Symptom: the handler or FIX session never connects, connects and drops straight away, or the venue rejects the logon.
Likely causes
- The host, port or multicast group in your settings doesn't match the venue's environment (production, certification or test).
- A firewall, VPN or cross-connect isn't open to that address.
- Credentials, SenderCompID or TargetCompID are wrong, expired or not yet enabled by the venue.
- The licence file is missing or has expired.
- Your handler version doesn't support the venue's current protocol or schema version.
Checks
- Read the handler log. Most failures are named there: connection refused, timeout, logon reject, or licence error.
- From the same host, test the TCP route with
nc -vz host portorTest-NetConnection host -Port porton Windows. - For multicast feeds, check that the host has joined the group and that packets arrive, with
tcpdump -n multicast -i. - Confirm with the venue which environment and credentials you have been given, and that your IP address is on their allow list.
- Check the licence file, as set out in Installing your licence file.
- Compare your handler version with the venue's current specification in the release notes.
Fix: correct the setting the log or checks point to, then reconnect. If the cause still isn't clear, email support@onixs.biz with the handler log, the handler version and the venue environment.
Each venue's programming guide sets out its connection settings; the guides are linked from the venue hubs in this category.
Documentation: Programming guides on ref.onixs.biz
Try it: Request a free 30-day evaluation
Questions? Email sales@onixs.biz