Skip to content
  • There are no suggestions because the search field is empty.

Sending one million FIX messages

How long the OnixS Java and .NET FIX Engines take to send a million orders.

OnixS measured how long its FIX Engines take to send one million New Order Single (35=D) messages from an initiator on one machine to an acceptor on a second, identical machine. The acceptor measured the time to receive them.

Engine and mode Total time Messages per second
Java, Onload and performance mode 0.31 s 3,197,647
Java, performance mode 0.53 s 1,876,835
Java, idle mode 4.45 s 224,796
.NET 5.0 0.44 s (sending) 2,274,190 sending, 1,808,499 receiving

 

Test set-up

  • Java: two Intel Core i9-12900KS machines, 32 GB RAM, Ubuntu 22.04, Java 11.0.21, Solarflare cards with Onload 8.1.3, 78-byte messages. TcpNodelay was on, and automatic SendingTime and header updates were off. Idle mode caps the CPU at 800 MHz; performance mode runs it at full speed.
  • .NET: two Intel Core i7-7700K machines, 32 GB RAM, Ubuntu 18.04, .NET 5.0, 150-byte messages, after 10,000 warm-up messages.

Results depend on hardware, network and settings, so measure on your own systems. Each full write-up includes the source code.

 

 

 

Documentation: Java results and .NET results on ref.onixs.biz
Try it: Request a free 30-day evaluation
Questions? Email sales@onixs.biz